THE WORLD'S FIRST DUAL-SOURCE & DUAL-DETECTOR CBCT SYSTEM

Using a dual-source generator and dual-detector design, Ultra3D contributes to a dual-system with wide-angle imaging and microscopic imaging that can provide micron-scale imaging solutions for ENT and dental clinical diagnosis.

PRE-SHOT POSITIONING SYSTEM

Ultra3D captures a large area with 2D image after will be select small area for 3D shooting, it will automatically direct the patient to the correct position with easy manipulation.

EXTRAODINARY IMAGE QUALITY

It provides a ten-micron class definition, body construction with 50µm can be detected easily, for in-depth diagnostic.

STARRY SKY DETECTOR

Equipped with high resolution, high sensitivity, high image acquisition rate, and a low power consumption core.

0.25 SMALL FOCAL SPOT X-RAY TUBE

Core technology for improving resolution and SNR.

THREE SUPPORTIVE ALGORITHMS

HD Reconstruction
Scatter Correction
Metal Artifact Reduction

LOW DOSE CONTROL

It fully explores the perfect balance between image quality and radiation dose. Low dose mode provides lower radiation especially for children and elders, that eliminates the risk of exposing the patient to an unnecessarily high dose by automatically adapting radiation levels.

MORE PRECISE MORE CONVENIENT

sponsor

Comfortable Table

The scanning table follows ergonomics to achieve smooth movement in six directions: up and down, left and right, and front and back, with 0.1 mm movement control accuracy. To reduce motion artifacts, the patients remain stable and comfortable during the whole procedure.

sponsor

Interaction System for Communication

Doctors can communicate with patients in real time. The console can control the switch and adjust the voice volume.

sponsor

Laser Projection

Optimaize positioning workflows with dramatically simplified laser projection system if the patient is positioned as accurate as possible.

sponsor

Outstanding Design

Both sides of the gantry channel are open so that patients can relax while being scanned.

PRODUCT PARAMETERS

  • sponsor

Specifications

  • Weight

    920 kg (2028.25 lb)

  • Product Dimension

    3.016 m (L, 9.90 ft)x 1.483 m (W, 4.87 ft)

  • Height

    1.6 m (5.25 ft)

Specifications Wide-angle Imaging System Microscopic Imaging System
Field of View (cm)
(Diameter × Height)
23×19 16×13 16×6 8x8 7×4
Spatial Resolution(lp/mm) ≥1.4 ≥1.4 ≥1.7 ≥1.9 ≥3.0
Voxel Size (mm) 0.15/0.3 0.125/0.25 0.1/0.2 0.075/0.15 0.05/0.1
X-ray Generator 1 X-ray Generator 2
0.5 (IEC60336) Nominal Focal Spot Size 0.25 (IEC60336)
60-100kV Adjacent Tube Voltage Increment 5kV Tube Voltage 60-120kV Adjacent Tube Voltage Increment 5kV
2-10mA Adjacent Tube Current Increment 0.5mA Tube Current 2-10mA Adjacent Tube Current Increment 0.5mA
1000W Maximum Power 1000W
Flat Panel Image Receiver 1 Flat Panel Image Receiver 2
Cesium Iodide + TFT Detector Type Cesium Iodide + CMOS
300×250 mm Effective Imaging Area 115×65 mm
100 µm Pixel Size 74.8 µm
3008×2496 Acquisition Matrix 1536×864
sponsor

3D Fine Reconstruction

Minimum voxel size to 0.05 mm.

Airway Measurements

Automatically calculate the volume and the narrowest area of the airway in the form of chromatographic visualization.

Medical Images Comparison

By loading multiple images, it is possible to perform single-slice comparison medical imaging. It can also compare multiple slices simultaneously by adjusting the layout view, as well as set multi-sequence synchronous page turning, zooming, panning, and adjusting window width and window level, thereby saving the comparison image function.

CPR-Surface Reconstruction

Precisely identify the centerline of the tubular structure based on a semi-automatic method. Visualize 3D curved tubular structures with advanced resampling algorithms to 2D image sequences, enabling intuitive inspection of tubular structures.

TMJ Diagnosis

SmartV-ENT has a visual pattern of comparison of left and right joints, allowing doctors to evaluate the diagnosis and treatment effect of temporomandibular joint diseases.

Implant Simulation

Neural tubes will be highlighted, which presents a relationship between the location of the implant and optimal length. This is the best way to improve the success rate for implant surgery.

Neural Tube Automatic Labeling

Label the neural tube automatically in the CT image, providing great convenience for diagnosis.

Regional Statistics

Used to evaluate bone mineral density in a selected area.